Mobile Chiller Support

Temporary Cooling & Mobile Chiller Support

Mobile air-cooled chiller solutions for early mechanical startup, phased turnover, and commissioning activities

Overview

Mobile Air-Cooled Chiller Solutions

Javelin provides mobile air-cooled chiller solutions to support early mechanical startup, phased turnover, and commissioning activities. These temporary systems allow project teams to begin equipment testing and system validation before the permanent cooling plant is energized or fully operational.

This positions Javelin as a full-spectrum mechanical readiness partner, supporting flushing, pre-commissioning, and temporary cooling needs throughout the data center construction lifecycle.

Mobile Air-Cooled Chiller Trailers

Available in capacities up to 660 tons each for large-scale temporary cooling requirements

Rapid

Deployment & setup

Full-Spectrum

Mechanical readiness

Heat pump Compressor hot water supply by heat exhanger to heating water for hotel or large commercial building roof top outdoor installation.

Our Capabilities

Complete mobile chiller deployment and integration services for data center mechanical commissioning

Mobile Chiller Deployment

Complete deployment of mobile air-cooled chillers, pumps, hoses, and manifolds for temporary cooling support during commissioning and startup phases.

  • Mobile air-cooled chillers
  • Pumps, hoses, and manifolds
  • Transportation and on-site setup
  • Equipment sizing and configuration

Hydronic Loop Integration

Temporary hydronic loop setup and integration with mechanical systems to enable CRAH/CRAC startup and equipment testing before permanent systems are operational.

  • Temporary hydronic loop setup
  • Integration with mechanical systems
  • CRAH/CRAC startup support
  • Loop balancing and equipment testing

Commissioning Coordination

Close coordination with mechanical and commissioning teams for phased cooling strategies that accelerate schedules and enable early equipment readiness.

  • Phased cooling strategy development
  • Coordination with mechanical teams
  • Early equipment testing support
  • System validation and startup

Monitoring & Operations

Continuous flow, temperature, and pressure monitoring with safe, controlled operation aligned to site procedures and owner standards throughout deployment.

  • Flow, temperature, pressure monitoring
  • Early-load requirement support
  • Safe, controlled operation
  • Alignment with site procedures
Pipeline system to deliver cold water into the production process.
Data Center Focus

Early Commissioning & Load Testing

Mobile chilled water systems are essential for data center commissioning and early occupancy. We provide temporary cooling capacity while permanent systems are being completed, allowing IT load testing, server installations, and customer migrations to begin ahead of schedule.

Accelerated Project Timelines

Commission data halls early while permanent chiller plants are still under construction—compressing project schedules and accelerating revenue generation.

IT Load Testing Support

Provide reliable cooling capacity for server installations, rack power testing, and full-load commissioning validation without waiting for permanent systems.

Seamless Transition to Permanent Systems

Coordinate handoff from temporary to permanent cooling with zero downtime, ensuring continuous uptime for mission-critical operations.

Equipment Inventory

Extensive fleet of mobile heating and cooling equipment ready for rapid deployment

Portable Chillers

Air-cooled and water-cooled mobile chiller units from 10 to 500+ tons capacity

Temporary Boilers

Mobile heating plants for construction and facility support applications

Air Handlers & Fans

Portable air handling units with ductwork for conditioned air distribution

Pumps & Piping

Temporary distribution piping, pumping stations, and hydronic accessories

Spot Coolers/Heaters

Portable units for targeted climate control in specific zones or rooms

Dehumidifiers

Moisture control equipment for construction drying and humidity management

Heat Exchangers

Temporary plate and frame heat exchangers for system isolation and bridging

Controls & Monitoring

Remote monitoring systems and control integration for continuous operations

Temporary Cooling Support Enables

Accelerated Commissioning Schedules

Mobile chiller systems enable equipment testing and system validation to begin before permanent cooling infrastructure is operational, reducing overall project timelines and accelerating turnover milestones.

Early Equipment Readiness Prior to Permanent Plant Turnover

Critical mechanical and electrical systems can be started up, balanced, and verified well in advance of the central plant being energized, enabling phased commissioning and reducing schedule dependencies.

Reduced Delays Related to Utility Availability or Central Plant Completion

Temporary cooling decouples commissioning activities from utility connections and permanent plant readiness, allowing critical path work to proceed without waiting for upstream system completion.

Smoother Mechanical and Electrical Integration Across Project Phases

Phased cooling strategies support coordinated startup sequences across MEP systems, reducing conflicts, improving system integration quality, and enabling more predictable commissioning outcomes.

Full-Spectrum Mechanical Readiness Partner

Javelin positions itself as a full-spectrum mechanical readiness partner, supporting flushing, pre-commissioning, and temporary cooling needs throughout the data center construction lifecycle.

System Flushing
Pre-Commissioning
Temporary Cooling